Customization: Available
Accuracy: ±0.2-0.5%
Main Application: Water
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

R&D Capabilities
The supplier has 14 R&D engineers, you can check the Audit Report for more information
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO14001
Product Certification
The supplier's products already have relevant certification qualifications, including:
Eco-friendly Product Certificate
to see all verified strength labels (26)
  • Hard Rubber Liner DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow Meter
  • Hard Rubber Liner DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow Meter
  • Hard Rubber Liner DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow Meter
  • Hard Rubber Liner DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow Meter
  • Hard Rubber Liner DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow Meter
  • Hard Rubber Liner DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow Meter
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
Overview

Basic Info.

Model NO.
AO-ATF
Size
DN10-500
Sensor
Tube/Flange
Application
Industrial Production
Type
Electromagnetic Flow Meter
Measuring Media
Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
CE, ISO
Power Supply
220V/24V/Battery
Signal Output
4-20mA; Pulse
Supply Voltage
110/220VAC ; 24VDC +10%
Compact Type
IP65
Body Material
Carbon Steel
Nominal Pressure
1.0~4.0MPa
Transport Package
Cartons and Wooden Box
Specification
DN10-500
Trademark
AUTEC
Origin
Fujin China
HS Code
9026100000
Production Capacity
2000

Product Description

Product Description

 

Electromagnetic flowmeter is composed of two parts: sensor and converter. It works based on Faraday's law of electromagnetic induction and is used to measure conductive liquids or two-phase media. Its conductivity is generally required to be greater than 5 μ S/cm (the original conductivity of tap water is about 100-500 μ S/cm). It can be used to measure various acid, alkali, salt solutions, pulp, slurry and other media, but the media cannot contain a lot of ferromagnetic substances and a large number of bubbles.

 

Electromagnetic flowmeter is a major flow meter widely used in industrial sectors such as petroleum, chemical, metallurgical, textile, papermaking, environmental protection, food, as well as municipal management and water conservancy construction for flow measurement.

 

    

Hard Rubber Liner DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow Meter
Hard Rubber Liner DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow Meter


    

 

 

The measurement system of the electromagnetic flowmeter sensor is based on Faraday's law of electromagnetic induction. A pair of detection electrodes are installed on the pipe wall perpendicular to the axis of the measuring tube and the magnetic field lines. When the conductive liquid moves along the axis of the measuring tube, it cuts the magnetic field lines and generates an induced potential. This induced potential is detected by two electrodes on the measuring tube, with a value of:

 

    

 

E=KBVD
Among them: E induced potential;

K instrument constant;

B magnetic induction intensity;

Measure the average flow velocity within the cross-section of the V measuring tube;

D Measure the inner diameter of the tube;

 

When measuring flow rate, the fluid flows through a magnetic field perpendicular to the flow direction, and the flow of conductive liquid induces an electric potential proportional to the average flow velocity. Therefore, it is required that the measured flowing liquid has a conductivity higher than the minimum limit. The induced voltage signal is detected through two electrodes. And it is transmitted to the converter through cables, and after signal processing and related operations, the accumulated flow rate and instantaneous flow rate are displayed on the converter's display screen.

 

Instrument features

 

1. There are no obstructions or moving parts inside the measuring tube, so it will not cause additional energy loss or blockage, resulting in significant energy-saving effects. It is particularly suitable for measuring liquid-solid two-phase flows such as sewage, mud, slurry, coal water slurry, pulp, etc.

2. Only the lining and electrode are in contact with the measured medium. As long as the lining and electrode materials are selected reasonably, good corrosion resistance and wear resistance can be achieved. Therefore, various chemical solutions such as strong acids and bases can be measured.

3. Low installation requirements. The front straight pipe section is only 5D, while the rear straight pipe section is 2D (D is the inner diameter of the selected instrument).

4. The measurement accuracy is not affected by changes in fluid density, viscosity, temperature, pressure, and conductivity, and can measure flow in both forward and reverse directions, which provides a good means for accurately measuring flow.

5. The power consumption of the instrument is low, less than 5VA.

6. The converter has good interchangeability and can achieve measurement accuracy without the need for re calibration of the real current. Due to its various advantages, electromagnetic flow meters are becoming increasingly widely used in various industries and have become the preferred instrument for liquid flow measurement.

Product Parameters

 

Ordering Instructions

Please read this information carefully before placing an order to understand the model and coding regulations of this product, and determine the model specifications as needed.

If necessary, please fill out the electromagnetic flowmeter selection operating condition table.

Technical parameters of AO-ATF-A/B (integrated/split type) universal electromagnetic flowmeter

1. Caliber DN10~DN2000

2. Electrode material 316 Hb,Hc,Ti,Ta,Pt

3. Inner lining materials PTFE, PFA, F46, chloroprene rubber, polyurethane

4. Dielectric conductive liquid (including solid-liquid two-phase)

5. Measurement errors of ± 0.3%, ± 0.5%, ± 1.0% flow rate (by caliber)

6. Dielectric conductivity>5 μ S/cm (water>20 μ S/cm)

7. Flow velocity range of 0.5-10m/s (flow unit can be selected)

8. Connect the flange according to the national standard GB9115 or according to user requirements

9. Integrated medium temperature -10 ºC~+60 ºC, split type -10 ºC~+150 ºC

10. Rated pressure 0.6MPa~4.0MPa (by caliber)

11. Protection levels IP65, IP67, IP68 (split type)

12. Converter with integrated or split design

13. Output signal 4-20mA output, frequency/pulse output

14. Communication RS485, RS232

15. Application of acid, alkali, water supply and drainage, food, pulp, slurry, etc

16. Display flow rate, flow rate, percentage, cumulative flow rate, fault alarm, etc

17. Power supply 220VAC, 24VDC

18. Installation form: integrated or split type

 

Technical parameters of AO-ATF-C/D (integrated/split) clamping electromagnetic flowmeter

1. Caliber DN10~DN200

2. Electrode material 316 Hb,Hc,Ti,Ta,Pt

3. Lining material PFA, F46

4. Dielectric conductive liquid (including solid-liquid two-phase)

5. Measurement errors of ± 0.3%, ± 0.5%, ± 1.0%

6. Dielectric conductivity>5 μ S/cm (water>20 μ S/cm)

7. Flow range 0.5-10m/s

8. Integrated medium temperature -10 ºC~+60 ºC, split type -10 ºC~+150 ºC

9. Rated pressure 1.6MPa~4.0MPa (by caliber)

10. Protection levels IP65, IP67, IP68 (split)

11. Output signal 4-20mA output, frequency/pulse output

12. Communication RS485, RS232

13. Application of acid, alkali, water supply and drainage, food, pulp, etc

14. Display flow rate, flow rate, percentage, cumulative flow rate, fault alarm, etc

15. Power supply 220VAC, 24VDC

16. Installation form: integrated or split type

 

Technical parameters of intelligent converter

conductivity

>5μS/cm

flow rate range

0.5~ 10m/s

current output

Bidirectional two-way, fully isolated, 0-10mA (load resistance 0-1.2K Ω),

 

4-20mA (load resistance 0-600 Ω)

 

Frequency output

The upper limit is set within 0-3KHz. Open collector output of transistor with photoelectric isolation

pulse output

The upper limit can reach 5000cp/s, and the pulse equivalent is 0.0001-10m3/cp. The pulse width is between 10ms and 2.5s. Transistor collector open circuit alarm output with photoelectric isolation, collector open circuit alarm output with positive and negative flow state. The external power supply for the above three outputs is not greater than 35V. When conducting, the collector current is 250mA

communication interface

RS485,RS232

quarantine

The insulation voltage between the analog output, pulse output, alarm output and the ground shall not be less than 500V

power supply

220VAC,24VDC

power

≤20W

ambient temperature

-10~+ 60ºC

display

High definition backlit LCD display, instantaneous, cumulative (forward cumulative, reverse cumulative, and differential cumulative)

power-off protection

Accumulated value data saved for more than 10 years

Shell protection

IP65,IP67,IP68(split type)

 

Company Profile

 

Founded in 2007, Fujian Aotai Automation Equipment Co., Ltd. is located in the beautiful Fuzhou, Fujian. It is an enterprise dedicated to providing measurement and control instruments and equipment for "intelligent manufacturing", "smart water" and "smart city". The company's goal is to become an enterprise with advanced technology, professional service and strong competitiveness in the industry. Since its inception, it has been adhering to the concept of "creating a century-old store and establishing a national brand", focusing on the research and development, production, sales and service of instrumentation, and striving to create value for customers.
Hard Rubber Liner DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow Meter

Hard Rubber Liner DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow MeterHard Rubber Liner DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow MeterHard Rubber Liner DN50 Water Magnetic Flow Meter Electromagnetic Mag Flowmeter Flow Meter

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
People who viewed this also viewed